Protection against ground moisture

Capillary rise through the foundation.

Fresh concrete gives off moisture for a long time.

Splashback around the ground connection, snow build-up, poor drainage.

All of them lead to the same place: moisture at the lowest junction of the building, where the structure begins.

Corrosion of steel requires sustained moisture. In a dry structure the life of a galvanised profile is comparable with that of the building. The base junction is where that condition is most easily broken.

On top of that, the alkalinity of fresh concrete attacks the zinc layer — so it is not enough for it to end up dry: it also has to be separated. Material pairing and corrosion.

Continuous, across the full width of the track, tied into the adjoining structures.

The structure should not begin at ground level: keeping splashback and snow away is simple, cheap protection.

Ground falling away from the building, rainwater led away, land drains where needed.

With a suspended floor, ventilating the space beneath it carries the vapour away.

  • interrupted damp-proofing at junctions and corners,
  • puncture at the fixings, if it is not dealt with,
  • later filling of the ground, which removes the protective height,
  • building in wet: moisture sealed in cannot get out later.

That last one matters particularly in a light gauge steel wall: whatever is built in has to be lived with for the whole service life of the structure.

The damp-proofing is under the track — not visible once erection is done. So photograph and record it at installation. The construction log.

The life of a steel frame is decided at the base junction. Damp-proofing done well here is worth more than any coating thickness.