Self-weight and imposed load

The weight of the structure and the layers on it. One of the best-known actions, so it gets a small partial factor.

  • Foundations: less load, a smaller foundation, a cheaper solution — a serious item on poor ground.
  • Rooftop additions: an existing building can often take exactly as much as a light structure adds. Rooftop additions.
  • Seismic action: the force from an earthquake is proportional to mass, so it is smaller for a light building.
  • Uplift: self-weight would work against wind suction, but there is little of it. Hence the need for strong anchorage.
  • Floor vibration: low mass gives a more sensitive floor.
  • Sound insulation: mass is one of the bases of airborne sound reduction, so what the structure does not give has to be made up in the build-up. Sound insulation basics.

The load from use: people, furniture, stored goods. The standard gives values by use — different for dwellings, offices and storage.

What to know in practice:

If a living room becomes an office, a store or a plant room, the load can change. That is a structural question as well as a permitting one.

Concentrated loads are a separate question

Section titled “Concentrated loads are a separate question”

A heavy piece of furniture, an aquarium, a plant item is not covered by the general imposed load. If such a thing is expected, say so in advance.

The weight of partitions is a load too — and if the occupant later builds a wall, the structure did not necessarily allow for it.

A light gauge steel building is not “weaker”, but the actions are defined more precisely, because there is no large reserve from mass. So ask the designer before a major alteration or a heavy installation.

The low self-weight is one of the technology’s greatest advantages — and precisely why uplift and vibration need separate attention.