Reaction to fire classes: from A1 to F

A1 — does not contribute to fire. Mineral wool, concrete, steel, glass.

A2 — effectively non-combustible, with negligible organic content.

B, C, D, E — increasing contribution to fire. B is still limited contribution; E only demonstrates short resistance to a small flame.

F — unclassified, or not meeting E.

Most fire casualties are caused not by flame but by smoke, and smoke also makes escape impossible. s1 means the least smoke. In a light gauge steel build-up this matters because the cavities of the structure can act as smoke paths.

This describes whether burning droplets or particles fall from the material. d0 means they do not. On escape routes and facades this is a critical property: falling burning material starts a new fire lower down.

A light gauge steel wall or floor build-up contains many materials side by side, and not all of them are asked for the same thing:

  • The lining protecting the structure is usually a high-class, fire resisting board, because it holds the heat back from the section.
  • The insulation class matters most where the regulation sets a requirement for the facade or for cavities — this decides whether mineral wool or an organic foam insulation can be considered.
  • Membranes and bonded layers are low in mass, but their smoke production is not zero.

Verifying the fire resistance of a structure. Even if every layer is A1, the wall will not automatically be REI 60 — load-bearing capacity depends on the heating of the section, not on the combustibility of the layers. On the relationship between the two: fire classification.

The material class says what the material adds to the fire. The structure still has to survive the required time — the two work together, they do not replace each other.