Wind barrier and breather membranes
The two membranes in the build-up
Section titled “The two membranes in the build-up”Inside: vapour control
Section titled “Inside: vapour control”It stops internal vapour getting into the structure. The principle of vapour control.
Outside: wind barrier, vapour permeable
Section titled “Outside: wind barrier, vapour permeable”It has three jobs:
- Wind barrier: stopping air from moving through the insulation. Insulation blown through performs substantially worse than the laboratory figure promises.
- Rain protection: keeping water that gets behind the cladding off the insulation.
- Vapour permeability: whatever the structure has taken up can leave outwards.
The basic rule
Section titled “The basic rule”Vapour permeability should increase outwards through the build-up. If the outer layer is tighter than the inner one, moisture is trapped.
So what goes on the outside of the insulation matters: a closed, vapour-resistant board there is as much a risk as bad vapour control inside.
The ventilated cavity
Section titled “The ventilated cavity”Many build-ups have a ventilated cavity behind the cladding. Its role:
- it drains away moisture that gets behind the cladding,
- it ventilates out the vapour heading out of the structure,
- it reduces the summer heat load.
In exchange it raises fire questions: the cavity needs cavity barriers. Fire spread on façades.
What to watch on site
Section titled “What to watch on site”- Laps and taping to the manufacturer’s instructions.
- Connection into the adjoining structures: windows and doors, the foundation junction, the roof.
- It must not be stretched taut between the sections, or it can tear at the fixings.
- Exposure time is limited: the UV resistance of the membrane is finite, so it cannot stay uncovered for months.
The drainage role
Section titled “The drainage role”In some build-ups the external membrane is also a secondary drainage layer: it collects and leads out the water that gets behind the cladding. The detailing then has to provide falls and an outlet — that is junction design.
The point
Section titled “The point”The external membrane is not “just a sheet of plastic”: it protects the performance of the insulation and it lets the structure dry. The wrong order here does as much harm as bad vapour control.